EventSeries® DMX Data Control Cable 500/600 V


Application
The DMX range complies with the requirements of DMX512-A and is an RS-485 based communications protocol that is most commonly used to control stage lighting and effects.
Cable Design
| Conductor | Stranded Tinned Copper (16 x 0,20 mm) 0,5 mm2 |
| Insulation | Foam Polyethylene Ø 1,8 ± 0,5 mm |
| Pair | 2 wires twisted to a pair |
| No. of Pairs | 1 Pair : Black, Red |
| 2 Pair : Black, Red, / Yellow, Green | |
| Drain Wire | Stranded Tinned Copper (16 x 0,20 mm) |
| Shield | Aluminium/polyester tape. (Aluminium inside) |
| Outer Jacket | LSZH FireFighter®, FRLS or TPE |
Characteristics
• Most commonly used to control stage lighting and effects
• Flame Retardant acc. to IEC 60332-1
• Halogen Free acc, to IEC 60754
• Smoke Density acc. to IEC 61034
Specification
| Part Number | Application | No. of Pairs | Type | Overall Diameter [mm] | Min. Bending Radius [mm] | Tray Rated Voltage [V] | Colour | Euroclass |
|---|---|---|---|---|---|---|---|---|
| DMX-01 | Patching | 1 | FRLS | 6,0 ± 0,3 | 60 | 500 | Black | Eca |
| DMXLSZH-01 | Install | 1 | LSZH FireFighter® | 6,0 ± 0,3 | 60 | 600 | Black | Dca-s2,d2,a1 |
| DMXLSZH-10 | Install | 1 | LSZH FireFighter® | 6,0 ± 0,3 | 60 | 600 | White | Dca-s2,d2,a1 |
| DMX-04 | Patching | 1 | FRLS | 6,0 ± 0,3 | 60 | 500 | Red | Eca |
| DMX-P-01* | Portable | 1 | TPE | 6,0 ± 0,3 | 60 | 600 | Black | Eca |
| DMX2LSZH-01 | Install | 2 | LSZH FireFighter® | 8,20 ± 0,5 | 90 | 600 | Black | Dca-s2,d2,a1 |